INSTALLATION
GAS HOOK-UP
LP TANK RESTRAINT FOR BUILT-IN INSTALLATION
If the grill is to be installed in a Built-in application, then the grill must be installed in accordance with the
Built-in installation guidelines.
If you intend to operate your Built-in grill on LP gas utilizing a 201b Type cylinder, then the Built-in LPtank
restraint must be installed prior to initial use of the grill. If you do not have one please contact DCS Customer
Care at (888) 936-7872 for information on obtaining one.
The following steps will illustrate how to properly locate and install the LP tank restraint within the Built-in
enclosure.
NOTE:
The grill comes with the LP Regulator/Hose assembly installed at the factory. The assembly, along with the entire grill
system, is leak tested.
Do not remove the Regulator/Hose assembly from the grill during installation.
The maximum distance from the center
of the manifold cut out to the center of
the tank restraint is 18 inches.
Tank Restraint can be placed
within this area without causing
stress on the LP regulator hose
connection.
', 18" max.
Center of manifold
cut out projected to
floor of the island.
Fig. 24