Liberty BFG-30 Manual
10
g
rill
exhaust
12" (to combustible construction)
10-1/16"
22-3/4"
25-1/2"
3/4"
2"
Standard layout for non-combustible enclosure:
NOTE: See page 9
for ventilation notes.
28-1/2"
Bottom of
support flange
28"
34-7/8"
23-3/4"
3-1/2"
18-1/2"
20"
11-1/8"
35-1/2"
Max.
opening for access doors/drawers
(see page 9 for ordering information)
4" x 4" opening
for gas supply line
opening for access doors
(see page 9 for ordering information)
4" x 4" opening
for gas supply line
22-3/4"
18-1/2"
20"
10-1/8"
35-1/2"
Max.
Layout for insulated jacket only - combustible enclosure:
NOTE: See page 9 for insulated jacket
part ord ering information.
28"
3
"
12" min.
INSTALLATION
BUILT–IN CONSTRUCTION DETAILS
Fig. 03
WARNING!
I
f installing the grill into a
non-combustible
e
nclosure, all combustible
c
onstruction must still be
outside the 12 inch
clearance zone. If your
island is made of stucco
over the top of wooden
studs, the wood can not be
inside the 12 inch
clearance zone to
combustible, even though
the stucco is what is
touching the grill area.