Manual

INSTALLATION
BUILT-IN CONSTRUCTION DETAILS
grill
exhaust
......... i ........3" (to non-combustible
construction / minimum
lid clearance)
12"(to combustible
construction)
'_Bottom of
supportflange
t
i
10"
Standard layout for non-combustible enclosure:
NOTE:If using a backguard
I . 1_ apmotor.............connectionll' locate
48" Models = 45-3/4" electrical service on the
36" Models = 34-1/2" right hand side for rotisserie
10 in,2Min. ventilation I
on the back side 3" Min. for Lid
Clearance
lOin,2min,
ventilation
le_ hand
side
22-3/4"
7._
4" x 4" opening
line
10 in.2min.
ventilation
on the right
hand side
35-1/2"
Max. opening for accessdoors/
1" Min. drawers
_J--J" ...... ..j/f 48" Models = 46" (see Fig.06 & 07 for
i. 36" Models = 34" ordering information)
Z_ WARNING!
If installing the grill into a non-combustible enclosure, all combustible
construction must still be outside the 12 inch clearance zone. If your
island is made of stucco over the top of wooden studs, the wood can not
be inside the 12 inch clearance zone to combustible, even though the
stucco is what is touching the grill area.
Layout for insulated jacket only - combustible enclosure:
10 in.2min. ventilation
on the back side
NOTE:If using a backguard
apron or rear wall, locate
I 48" Models = 51-5/8" I electrical .... i..... the36" Models = 40-1/2" right hand side for rotisserie
J motor connection
J
3" Min.for Lid
Clearance
10in.2min.
ventilation
left hand
side
I
35-1/2"
Max.
23-3/4"
4" x 4" opening
for gas supply
line
10 in.2min.
ventilation
on the right
hand side
opening for access
doors/drawers
[ !
48" Models = 46" ordering information)
36" Models = 34"
INSULATEDJACKET
Size Part No,
36 70167
48 70 72
FIG. 05
10