Manual

INSTALLATION
INSTALLER CHECKLIST
Fj Specified clearances
maintained to
combustibles.
rj Verified proper enclosure
ventilation.
Fj All internal packaging
removed.
rj Removed shipping
brackets
rj Knobs turn freely, bezels
centered.
Each burner lights
satisfactorily, individually
or with adjacent burner
lit.
Fj Air shutters adjusted. Fj
rj Low flame setting
satisfactory.
rj Drip pan in place properly
and sliding freely.
Fj Pressure regulator
connected and set for 4.0"
W.C. Natural, 11.0" W.C. LP
gas.
rj Manual shut-off valve
installed and accessible.
rj Unit tested and free of
leaks.
User informed of gas
supply shut-off valve
location.
rj All radiants are assembled
and put in place.
rj Check match lighting.
PLEASE LEAVE THESE
INSTRUCTIONS WITH THE
USER.
USER, PLEASE RETAIN
THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
NOTE:
If any of the listed items are missing, contact DCS at (888) 936-7872. Please be prepared with your
Model #, Serial # and description of item(s) that are missing.
Tag location of
Model # and Serial #
Read all installation instructions in this manual to see if the unit has been properly installed. If not done or
done correctly, correct before using the unit.
19