Service manual
TIMERS AND MODE SECTIONS-(S1 and S2)
FULL SPEED RUN TIMER- SWITCH PACK S1 (1-5)
SECONDS---------- 1 2 4 8 16
S1
SHOWS DEFAULT SETTINGS
1 2 3 4 5 6 7 8
FAST RUN TIMER 1-5 | MODE SELECTION 6-8
MODE SELECTIONS- SWITCH PACK S1 (6-8)
SWITCH - 6. FAIL SECURE MODE, (VER 6.351 or higher) with AC power off, in continuos battery back up mode (S2 #8
off) gate will not auto open if batteries get low. If batteries are low, gate will stay open after a open command is given.
SWITCH - 7
. Changes the direction of operation. OFF=Right hand, ON= Left hand. (see page 8)
SWITCH - 8
. NOT USED AT THIS TIME (ver 6.34 or higher only)
CLOSE TIMER- SWITCH PACK S2 (1-5)
On the MEGA-SWING-UL the switches 1-5 on S2 are for the closing timer delay. If S2-7 is on, the gate will auto close by
timer. Default is S2-3 "on" to provide a 4 second delay if activated.
SECONDS---------- 1 2 4 8 16
S2
SHOWS DEFAULT SETTINGS
1 2 3 4 5 6 7 8
CLOSE TIMER 1-5 | MODE SELECTION 6-8
MODE SELECTIONS- SWITCH PACK S2 (6-8)
SWITCH - 6. Sets aux. open input terminal #4 at J5 to be pulse open--pulse close (example: residential applications).
SWITCH - 7 AUTO CLOSE TIMER.
Default is OFF. When on, use S2 1-5 to set close time delay.
When close timer is selected, YOU
must install vehicle and pedestrian detection devices. It is strongly recommended that
photo electric beams (eyes) be installed on BOTH
sides of swing gate to reduce the possibility of injury to persons that
may attempt to walk through gate opening. Along with the beams, it is strongly recommended
that pressure sensing
edges be install leading edge of the gate panel, and any area that presents a PINCH POINT
or risk of ENTRAPMENT.
SWITCH - 8 AUTO OPEN ON POWER FAILURE. When switch number 8 is in the ON position, the operator will
automatically open the gate approximately 15 seconds after the loss of power. Once power is restored the operator will
resume normal operation.
Page 7