Service manual

SAMPLE CONFIGURATIONS
SAFETY
LOOP
MEGA SWING-UL
CARD READER
TELE-ENTRY
RADIO CONTROL
DUAL DIRECTION AS ENTRY AND FREE EXIT:
ENTRY WITH ACCESS CONTROL DEVICE:
FREE EXIT ON VEHICLE APPROACH:
GATE WILL OPEN WHEN SENSED BY
OPEN LOOP AND THEN CLOSE ONCE
CLOSE TIMER IS ON. CLOSE INPUT CAN B
E
USED TO CLOSE GATE BEFORE TIMER EX
ALL LOOPS ARE CLEARED IF THE
GATE WILL OPEN WHEN ACTIVATED BY AN
ACCESS CONTOL DEVICE. WHEN TIMER
EXPIRES (IF USED) GATE WILL CLOSE
DUAL DIRECTION IS A COMBONATION OF
BOTH OF THE ABOVE CONFIGURATIONS
TO PROVIDE THE ABILITY FOR TRAFFIC
TO ENTER OR EXIT IN THE SAME LANE.
TERMINAL # 1,2,3 IS OPEN INPUT.
TERMINAL # 5 IS SAFETY INPUT.
TERMINAL # 5 IS SAFETY INPUT.
TERMINAL # 1,2,3 ARE OPEN INPUTS.
OPEN LOOP
(FREE EXIT)
SAFETY
LOOP
SAFETY
LOOP
MEGA SWING-UL
CARD READER
TELE-ENTRY
RADIO CONTROL
SAFETY
LOOP
LOOP
MEGA SWING-UL
OPEN
SHADOW
LOOP
SHADOW
LOOP
SHADOW
LOOP
TERMINAL #8 FOR SHADOW LOOP.
TERMINAL #8 FOR SHADOW LOOP.
TERMINAL # 1,2,3 IS OPEN INPUT.
TERMINAL # 5 IS SAFETY INPUT.
TERMINAL #8 FOR SHADOW LOOP.
SAFETY AND OPEN LOOPS SHOULD BE 4 FEET FROM
EACH OTHER AND FROM THE GATE LEAF TO AVOID
LOOP CROSS TALK AND FALSE DETECTION OF GATE.
DO NOT ALLOW CONTROL DEVICES TO BE WITHIN (10 FEET) OF GATE OR OPERATOR
RECOMMENDATION 1: If vehicle detectors are used to open or close the gate, use of the presence
contacts are recommended. Using the pulse contacts will
REDUCE the gates safe operation.
RECOMMENDATION 2: Use safety pressure sensing edges to prevent entrapment.
RECOMMENDATION 3
: Install ALL access control devices within view of gate. PAGE 10