User guide
Developers guidelines | AT commands
231 June 2010
Test command: AT*EBCA=? Shows if the command is supported.
Test command
response: *EBCA: (range of <onoff>)
Parameters:
<onoff>:
<onoff> Description
0 Disable unsolicited result code *EBCA. Default
value
1 Enable unsolicited result code *EBCA
<vbat> Battery voltage in number of mV. Range 0–65500.
<dcio>: Battery voltage from the charger in mV. Range 0–65500.
<icharge>: Current charge in mA. That is, a value of 1A is reported as 1000. Range 0–
65500.
<iphone>: Phone current consumption in mA. That is, a value of 1A is reported as
1000. Range 0–65500.
<tempbattery> Signed integer. Battery temperature in °C, -20 to +70.
<tempphone>: Signed integer. Phone temperature in °C, -20 to +70.
<chargingmethod>: Integer.
<chargestate>:
<chargestate> Description
0 Start
2 Charge – Charging the battery until it is fully
charged
3 Await – The battery temperature is outside the limits
for normal charging
4 Await, extended temperature – The battery
temperature is outside the limits for maintenance
charging
5 Await, safety timer – The safety timer has expired.
Further charging is disabled for as long as the
charger is connected
7 Handheld – No charger is attached
8 Charge completed – Maintaining the charge of a
fully charged battery
15 Paused – Charging is paused by the user
<remcapacity>: Integer. Remaining capacity in mAh.
<remcapacitypercent
>:
Integer. Remaining capacity in percent. Range 0–100%.
<powerdissipation>: Integer. The FET power dissipation in mW.
<noccycles>: Integer. The number of completed charging cycles.
<nosostimer>: Integer. The number of seconds on the safety timer.
<suspensioncause>: Integer. The cause for suspension of charging.