SELECT LOCATiON
The proper location will ensure peak performance of your appliance. Choose a location where the unit will be out of rain
and direct sunlight and away from heat sources. Best performance will be maintained when installed within the following
parameters:
IDEAL AMBIENT TEMPERATURE RANGE*
Built-In 55-80 degrees F
Freestanding 55-90 degrees F
*Ice Maker will not perform correctly in ambient temperature less than 55 degrees F.
CABiNET CLEARANCE
Ventilation is required from the bottom front section of the unit where the grill
is located. Keep this area open and clear of any obstructions.
Adjacent cabinets and countertop can be built around the unit as long as no
top trim or countertop is installed lower than the top of the hinge. The unit
must be able to be removed from the cabinet for service.
SiDE TRiM iNSTALLATiON:
Attach side trim to the inner side of the cabinet so that the trim faces outward
(away from the appliance’s door) and fasten with appropriate screws suitable
for the type of cabinet material.
LEvELiNG LEGS
Make certain your ice maker is level. Adjustable legs at the front corners of the
unit should be set so the unit is firmly positioned on the floor and the front is
raised just enough so that the door closes easily when opened about halfway.
Turn leveling legs clockwise to raise unit, counterclockwise to lower it.
ELECTRiCAL CONNECTiON
Check the serial nameplate for the correct power supply. Use only the electri-
cal power supply specified on the serial nameplate (the serial plate is located
on the lower right side of the inside front panel- see Fig. 02). DO NOT USE AN
EXTENSION CORD.
GROUNDiNG METhOD
This product is factory equipped with a power supply cord that has a three-pronged,
grounded plug. It must be plugged into a mating grounding type receptacle in accor-
dance with the National Electrical Code and applicable local codes and ordinances (see
Fig. 04. If the circuit does not have a grounding type receptacle, it is the responsibil-
ity and obligation of the customer to exchange the existing receptacle in accordance
with the National Electrical Code and applicable local codes and ordinances. The third
ground prong should not, under any circumstances, be cut or removed. All U.L. listed
refrigerated products are equipped with this type of plug.
WARNiNG
This unit should not, under any circumstances, be ungrounded.
Fig. 04
Island Preparation
Side Trim Installation
Mounting
screws not
provided
Fig. 03