Installation Guide

9
US
CA
USING YOUR ELECTRONIC CONTROL
Temperature Sensor Fault: If the control-
ler detects that the temperature sensor is not
properly functioning, a temperature sensor
alarm will sound in one (1) second intervals. "E1" will ash
on the display panel and the Alarm LED located at the top
left of the display below the word "Alarm" will be illuminated.
High and Low Temperature Alarm: If your
unit reaches an unacceptable temperature
outside of your set-point, the alarm will sound
in (1) second intervals. The display panel will
ash either "Hi" or "Lo" depending upon the
condition and the Alarm LED light at the top
left of the display below the word "Alarm" will be illuminat-
ed. These alarms indicate that the compartment tempera-
ture has moved 10° or more from the set point for more
than 1 hour duration. The alarm will remain active until the
condition is corrected.
NOTE
During initial appliance start-up, the high temperature alarm
may sound until the interior temperature reaches set point.
The high temperature alarm can also occur if the door re-
mains open during an extended period of time (i.e. cleaning
or door ajar alarm condition), high usage or loading with
warm product. After a high temperature alarm condition check
all perishables to ensure they are safe for consumption.
Alarm Mute
Press any key to mute the audible portion of an alarm.
NOTE
This action will only mute the alarm. If the condition that
caused the alarm continues, the alarm code will continue to
ash and will sound for 20 seconds every 60 minutes.
Starting your beer dispenser
Plug the beer dispenser power cord into a wall outlet. Your
beer dispenser will begin cooling after power is applied.
If your beer dispenser does not start, check that the beer dis-
penser is turned on and the set temperature is cold enough.
Turning your beer dispenser ON or OFF
If the beer dispenser is on, the beer dispenser temperature
will be shown on the display. To turn the beer dispenser
off, press and hold the "ON/OFF" button for three seconds.
"OFF" will appear on the display.
If the beer dispenser is not on, "OFF" will be shown on the
display. To turn the beer dispenser on, press and hold the
"ON/OFF" button for three seconds. The beer dispenser
temperature will be shown on the display.
Set temperature
To set the beer dispenser temperature, press and hold
the "SET" button. When the "SET" button is pressed, the
display will show the set temperature. While holding the
"SET" button, press the "WARMER" or "COLDER" buttons
to adjust set temperature.
Beer dispenser operation
The available temperature range of the beer dispenser is
34 to 46°F (1 to 8°C).
It may take up to 24 hours for your beer dispenser to reach
desired temperature. This will depend on amount of content
loaded and number of door opening and closings.
For best results allow beer dispenser to "pull down" to
desired set temperature before loading. Once contents are
loaded, allow at least 48 hours for temperature to stabilize
before making any adjustments to the set temperature.
Alarms
Your digital display function will monitor beer dispenser
function and alert you with a series of audible and
visual alarms.
Door Ajar Alarm: If the door has been left
open for over ve minutes, the alarm will
sound in one second intervals. The display
panel will ash "do" and the Alarm LED located at the top
left of the display below the word "Alarm" will be illuminat-
ed. This will stop as soon as the door is closed.
Set
Colder Warmer
ON/OFF
Press and Hold Press and Hold
Alarm
F
Figure 11
Figure 10
close-up of control