user guide

12
LOW FLAME ADJUSTMENT
The valves on the side burner feature an adjustable low setting. Due to fluctuations in gas
pressure, or heating value you may feel it necessary to increase or decrease gas flow in the
low position. If the gas type has been converted from natural to LP or vice-versa, the low
flame setting must be reviewed and adjusted.
1
3
4
2
Remove the dial.
While holding the valve shaft with
pliers, insert a flat-tipped screwdriver
into the shaft and, while viewing the
burner, adjust to a minimum stable
flame.
Push in and hold the selected dial
for 2 seconds before turning to HI.
Hold for 10 seconds to light the
selected burner.
Turn the control dial counter-
clockwise to the lowest setting.
BEZEL FRONT VIEW