Specifications

UC864-E/G/WD/WDU AT Commands Reference Guide
80304ST10041a Rev. 7 - 2010-10-14
Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved. Page 98 of 318
+CIND - Indicator Control
[,<state>[,…]]] associated indicator changes. The supported indicators (<descr>) and their
order appear from test command AT+CIND=?
Parameter:
<state> - registration state
0 - the indicator is deregistered; there’s no unsolicited result code (+CIEV
URC) automatically sent by the ME to the application, whenever the
value of the associated indicator changes; the value can be directly
queried with +CIND?
1 - the indicator is registered: an unsolicited result code (+CIEV URC) is
automatically sent by the ME to the application, whenever the value of
the associated indicator changes; it is still possible to query the value
through +CIND? (default)
AT+CIND? Read command returns the current value of ME indicators, in the format:
+CIND: <ind>[,<ind>[,…]]
Note: the order of the values <ind>s is the same as that in which the
associated indicators appear from test command AT+CIND=?
AT+CIND=? Test command returns pairs, where string value <descr> is a description
(max. 16 chars) of the indicator and compound value is the supported values
for the indicator, in the format:
+CIND: ((<descr>, (list of supported <ind>s))[,(<descr>, (list of
supported <ind>s))[,…]])
where:
<descr> - indicator names as follows (along with their <ind> ranges)
“battchg” - battery charge level
<ind> - battery charge level indicator range
0..5
99 - not measurable
“signal” - signal quality
<ind> - signal quality indicator range
0..7
99 - not measurable
“service” - service availability
<ind> - service availability indicator range
0 - not registered to any network
1 - registered
“sounder” - sounder activity
<ind> - sounder activity indicator range
0 - there’s no any sound activity
1 - there’s some sound activity