Specifications

UC864-E/G/WD/WDU Product Description
80281ST10034a Rev. 4 – 2009-06-24
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 24 of 57
3.10 WCDMA/GSM Power consumption
The typical current consumption of the Telit UC864 family is:
Power off current (typical)
< 26 μA;
Stand–by current (WCDMA Idle)
< 22mA (<4.1mA using command AT+CFUN=5)
Stand–by current (GSM Idle)
< 15.0mA (<3.3mA using command AT+CFUN=5)
Operating current in WCDMA voice channel
< 690 mA @ worst network conditions
Operating current in GSM voice channel
< 317 mA @ worst network conditions
Operating current in WCDMA data channel
< 680 mA @ worst network conditions
Operating current in HSDPA channel
(HSDPA for UC864-E/G only)
< 730 mA @ worst network conditions
Operating current in GPRS Class 12
< 790 mA @ worst network conditions
Operating current in EGPRS Class 12
< 560 mA @ worst network conditions