4.2 User settings
4.2.1. Setting the time
1. Select the HRE channel with the
(
and
)
keys.
2. Press the
B
key for 2 seconds.
3. Set the hour with the
(
and
)
keys.
4. Press the
B
key to confirm.
5. Set the minutes with the
(
and
)
keys.
6. Press the
B
key to confirm.
CAUTION
The controller does not switch between summer and
winter time.
4.2.2. Force back-up
1. Select the RAP channel with the
(
and
)
keys.
2. Press the
B
key for 2 seconds. The symbol
T
flashes.
3. Set the RAP parameter to ON using the
)
key.
4. Press the
B
key to confirm the setting.
The electrical back-up shuts down when the set point
temperature is attained.
4.2.3. Modifying the back-up authorisations
Throw the switch to modify the electrical back-up authorisations.
E
Winter: Electrical back-up is authorised day and night.
0 Electrical back-up is not authorised. No back-up heating.
Z
Summer: Electrical back-up is only authorised at night.
The back-up is deactivated if the solar pump is running.
4.2.4. In the event of prolonged absences
In the event of prolonged absence, shut down the electrical back-up
if the function is activated and reduce the setpoint of the solar DHW
tank: