User guide
29
2 / INSTALLING YOUR APPLIANCE
EN
Tip
Adjust the level of your hood before
fully tightening up the four D and E screws.
ASSEMBLING THE HOOD
Warning
The hood must be installed in
compliance with all applicable regulations
concerning the ventilation of premises. In
France these regulations are described in
DTU 61.1 from the CSTB. In particular, the
evacuated air should never be conveyed to a
duct used to evacuate smoke from
appliances that use gas or other combustible
fuels. Unused ducts may only be used after
approval from a competent specialist.
The minimum distance between the cooking
surface and the lowest part of the hood must
be 70 cm. If the instructions for the hob
installed under the hood specify a distance of
more than 70 cm, this requirement must be
respected.
— Draw a horizontal line 70 cm minimum from
the cook top (fig. 1).
— Draw a vertical line (B/fig. 1) on the wall that is
centred over the cook top and that extends
from the horizontal line drawn in the previous
step (A) to the ceiling.
— Cut the drilling template by following the
dotted lines to obtain two parts, C1 and C2
(fig. 1).
— Place the C2 template (fig. 1) on the wall,
superimposing the line that represents the
hood's axis over vertical line B (fig. 1) drawn in
a previous step.
— Place the C1 template (fig. 1) against the wall
flush with the ceiling.
— Drill the six holes. Insert the 6 wall plugs.
FFoorr tthhee DDHHDD112200XXEE mmooddeell,, ffoollllooww tthhee aaddddiittiioonnaall
iinnssttrruuccttiioonnss ((ffiigguurree 22)) oonn tthhee ffoolllloowwiinngg ppaaggee..
— Screw in the top two screws for the hood
(D/fig. 1), leaving 5 mm sticking out from the wall.
••
=
=
> 70 cm
5mm
x 2
fig. 1
A
B
E
D
C1
C2
99636271_ML_A.qxp 20/06/2005 11:22 Page 29