Operation Manual

19GB
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
The filter is not washable and cannot be
regenerated. It must be replaced when led S1
flashes or at least every 4 months. The alarm
signal will only light up when the extractor
motor is switched on.
Alarm signal reset
Switch off the lights and extractor motor.
Press button T3 for at least 3 seconds, until the
leds start to flash.
Replacing the Filter
Remove the metal grease filters
Remove the saturated activated carbon filters
as shown (A).
Fit the new filters (B).
Replace the metal grease filters.
Alarm signal activation
In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a
later date. Turn the Lights and the suction Motor off.
Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply.
Restore the connection by pressing and holding T1.
Release the button. All five LEDs are turned on
Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
LED flashes twice - Activated charcoal filter saturation alarm ENABLED
LED flashes once - Activated charcoal filter saturation alarm DISABLED
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Remove the light cover by unfastening the
screws that hold it.
Extract the lamp from the Support.
Replace with another of the same type, making
sure that the two pins are properly inserted in
the lamp holder socket holes.
Replace the light cover.
A
B