Operation Manual

2 / INSTALLING YOUR APPLIANCE
EN
ELECTRICAL CONNECTION
Single-phase 20A Meter
220-240V
~
50Hz
Electrical outlet
2 poles
+ earth
standard CEI 60083
220-240 V
~
Single-phase line
Power
supply cable
length 1.50 m
approx.
16A fuse or differential
circuit breaker
The appliance must be fitted correctly to
guarantee electrical safety. During fitting and
maintenance operations, the appliance must
be unplugged from the electrical grid. Fuses
must be switched off or removed.
The electrical connections are made before
the appliance is installed in its housing.
Ensure that:
- the electrical installation has sufficient
voltage,
- the electrical wires are in good condition,
- the diameter of the wires complies with the
installation requirements.
Your oven must be connected with a
(standard) power cable with 3 conductors of
1.5mm
2
(1 live + 1 neutral + earth) which must
be connected to a 220-240V
~
single-phase
grid by means of a 1 live + 1 neutral + earth
CEI 60083 standard power socket or via an
Warning
The safety wire (green-yellow) is
connected to the appliance’s terminal
and must be connected to the earth terminal
of the electrical set-up.
If the connection is to an electric wall socket,
it must remain accessible after installation.
The fuse in your set-up must be 16 amperes.
all-poles cut-off device, with minimum opening
between contacts of 3 mm, all-poles cut-off
device in compliance with the installation rules.
42