User guide
7
2 / INSTALLING YOUR APPLIANCE
EN
••
ELECTRIC CONNECTION
Single-phase 20A Counter
220-240V
~
50Hz
Electrical outlet
2 prong receptacle
++
eeaarrtthh
CEI Standard 60083
220-240 V Single-phase
line
~
Power
supply cable
length 1.50 m
approx.
16A fuse or differential
circuit breaker
The appliance must be fitted correctly to gua-
rantee electrical safety. During fitting and
maintenance operations, the appliance must
be unplugged from the electrical grid; fuses
must be switched off or removed.
The electrical connections are made before
the appliance is installed in its housing.
Ensure that:
- the electrical installation has sufficient volta-
ge,
- the electrical wires are in good condition,
- the diameter of the wires complies with the
installation requirements.
The oven must be connected with a power
cable (standardised) with 3 1.5mm
2
conduc-
tors (1 ph +1N + ground) that must be connec-
ted to a monophase 220-240 V
~
network via a
CEI 60083 standardised receptacle 1 ph + 1
neutral + ground lead or an all-pole cut-off
device in accordance with installation rules.
Warning
The safety wire (green-yellow)
is
connected to the appliance’s terminal
and must be connected to the earth terminal
of the electrical set-up.
You must enable the appliance to be discon-
nected from the supply network after instal-
lation.
Disconnection can be enabled by ensuring
that there is an accessible power plug or by
incorporating a switch into the fixed wiring in
compliance with the installation rules.
The fuse in your set-up must be 16 amperes.
If the power cable is damaged, it should be
replaced by the manufacturer, its after-sales
service department or a similarly qualified
person to avoid danger.