Operation Manual

217638216-02 - 19062015 KALIKO SPLIT
5 Using the appliance
5 Using the appliance
5.1 Using the control panel
5.1.1 First time commissioning
Caution
Only a qualified professional may carry out first
time commissioning.
1 Connecting the system to the mains
Fig.10 Start-up
Timer 1
On Off
Timer 2
On Off
Set Temp
Error
Electrical
Heating
Heating
NIE-A-055
Electrical
Heating
Enter
Timer /
Clock
Starting up the thermodynamic water heater:
2 Press the MODE key (in residence). The operating indicator light
comes on.
Note
Pressing the MODE key a second time puts the appliance in
holiday mode. The operating indicator light goes off.
Fig.11 Check
Timer 1
On Off
Timer 2
On Off
Set Temp
Error
Electrical
Heating
Heating
NIE-A-056
Enter
Electrical
Heating
Timer /
Clock
3 Check that no error codes or messages are shown on the display.
The domestic hot water set point temperature is set to 50°C in the
factory.
The compressor starts up after 3 minutes if domestic hot water production
is required.
Note
To speed up the heating process, select the operating mode:
electrical back-ups § 5.1.5
The appliance will automatically return to normal operating
mode once the temperature set point has been reached.