1 Safety Instructions
1.3 Specific safety instructions
Warning
Refrigerant fluid and pipes:
Use only R-134a refrigerant fluid to fill the
system.
Use tools and pipe components especially
designed for use with R-134a refrigerant fluid.
Use copper pipes deoxidised with
phosphorus to carry the refrigerant fluid.
Use beading to guarantee the tightness of the
connections.
Store the refrigerant connection pipes away
from dust and humidity (risk of damage to the
compressor).
Cover both ends of the pipes until the
beading process.
Do not use a load cylinder.
Regarding information on installation on
the appliance, electrical connection and
connection of the water circuit, refer to the
paragraphs below in this manual.
Regarding information on handling, servicing
and scrapping the appliance, refer to the
paragraphs below in this manual.
Note
In order to limit the risk of being scalded, the
installation of a thermostatic mixing valve on the
domestic hot water flow pipes is recommended.