Owner's Manual

15
GB
Troubleshooting
PROBLEM CAUSE REMEDY
The air
conditioning unit
does not start.
No electricity.
It is not plugged into the outlet.
The safety device of the plug has
tripped.
The internal safety device has tripped.
Restore electricity.
Plug into the outlet.
Reset the safety plug.
Wait 30 minutes, if the pro-
blem persists, contact your
service center.
The air
conditioning unit
works for a short
time only.
The air exhaust hose has a constriction.
The air exhaust hose is blocked.
There are tight bends in the air exhaust
hose.
Position the exhaust hose
correctly.
Check there are no
obstacles Obstructing air
discharge.
Eliminate the tight bends.
The air
conditioner
works, but does
not cool the
room.
Window open.
There are heat sources in the room
(lamps, etc.).
The exhaust hose is detached.
Air filters clogged.
Close the window.
Eliminate the heat source.
Connect the exhaust hose.
Clean or replace the filters.
Clean or replace the filter.
Bad odor in the
room.
The filter is clogged.
The air
conditioner does
not operate for
about 3 minutes
after turning it on.
The internal compressor safety device
prevents the appliance from being
restarted until three minutes have ela-
psed since it was last turned off.
Wait. This delay is part of
normal operation.
/ PF/
appears on the
display.
The appliance has a self diagnosis
system to identify a number of malfunc-
tions.
See the self-diagnosis chap-
ter.
NOTE:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS,
WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the
unit has been on its side, oil needs to return to the compressor to ensure proper function. With-
out allowing the unit this time (6-24 hours) the unit may function for only a short time, and then
the compressor will break down from lack of oil.
TROUBLESHOOTINGng