PAC600T • Use and maintenance manual . . . . pag. 4 • Mode d’emploi et d’entretien . . . . . pag. 16 • Instrucciones de uso . . . . . . . . . . pag. 28 • Manual de instruções . . . . . . . . . . pag.
I m p o r t a n t s a f e g u a rd s • Use this appliance only as described in this instruction manual. As with any electrical appliance, whilst the instructions aim to cover as many eventualities as possible caution and common sense should be applied when operating and installing this air conditioner. • This appliance has been manufactured to cool and de-humidify domestic environments and should not be used for other purposes. • It is dangerous to alter or modify the unit's characteristics in any way.
D uring the summer, optimum comfort is achieved with a temperature of around 75°F (24 °C) and 50% relative humidity. An air conditioner removes moisture and heat from the room where it is located. One advantage of portable air conditioning units over fitted models is that they can be moved from one room to another in the home or even transferred between different buildings.
Setting up The following instructions will help you set up your air conditioning unit as efficiently as possible. AIR CONDITIONING WITHOUT INSTALLATION FOR INSTANT TEMPORARY USAGE With just a few simple operations, Pinguino will restore comfortable conditions in your room: • With a double casement window, use the suckers 27 provided to hold the two halves of the window together (fig. C). • Fix the exhaust hose 25 to the coupling 8 on the back of the unit as shown in figure A.
AIR CONDITIONING WITH INSTALLATION For more efficient use Pinguino can also be semi-permanently installed • Fit the flange 24 supplied to the hole. • Fix the hose 25 to the coupling on the back of the unit (figure A). • Attach the end of the hose 25 to the flange 24 as shown in the figure F. F MAX 47" (120 cm) 12" 30 cm 12" 30 cm To install, proceed as follows: • Make a hole in a outside wall or through the glass of a window.
Pre p a ra t i o n f o r u s e HOW TO USE THE AIRCONDITIONER WITH WATER These air conditioners can use both air and water to cool the condenser (the hot part) of the air conditioner. To utilise the full potential of your air conditioner, the tank 5 needs to be filled with water. The water is used to increase the cooling power and reduce the noise level and energy consumption of the air conditioner.
ELECTRICAL CONNECTION PROGRAMMED MODE Before plugging in check that: • the mains supply corresponds to the power supply shown on the rating plate; • the socket and the mains lead correspond to the power requirements of the appliance; • the socket is suited to the plug, otherwise have the socket replaced; • the socket is properly grounded. 1) Set the operating times by pushing out the notches on the dial corresponding to the period required (each notch represents 15 mins.
Selecting functions AIR CONDITIONING FUNCTIONS COOL JET To turn the unit on in air conditioning mode, proceed as follows: The cool jet mode was conceived to provide the appliance with a greater cooling potential. This is particularly useful when you want to bring the temperature of a very warm room quickly down to a more comfortable level. In this case: Make sure that the tank is full of water (see page 8); Make sure that the function selector switch 1.
PURIFICATION FILTER In addition to dust, this purification filter is able to capture even the smallest sized particles and impurities (up to 0.003 millimetres), such as cigarette smoke. The purification filter should never be used with the dust filter, which is also included with the appliance. Therefore: A. If you wish to use the purification filter: Remove the purification filter from the filter housing; Remove the aspiration grill 7 (fig. H on page 12) and the dust filter which is attached to this.
Maintenance Before cleaning or maintaining the unit, always turn the unit off by releasing the ON/OFF button 11 and unplug from the mains . CLEANING THE APPLIANCE We recommend cleaning the appliance with a slightly damp cloth then drying with a dry cloth. For safety reasons, do not wash the air conditioner with water. Precautions Never clean with benzene, alcohol or solvents. Never spray liquid insecticide or similar.
ENGLISH De s c a l i n g When the scale deposits become excessive (on average, after about 400 hours of operation) or in any case, at least once each season, it is very important to proceed with the decalcification of the appliance as described below. To remove the scale from the appliance, you need: • 20% of descaling liquid 29 • 80% of clean water (corresponding to a diluted solution of 75%) fig.
Troubleshooting If the unit is not working properly, this may be due to small problems that you can easily resolve yourself. Follow these instructions carefully before contacting your local Authorised Technical Service Centre.
TECHNICAL SPECIFICATION Power supply see rating plate Max. absorbed power in air conditioning “ Refrigerating capacity “ Refrigerant “ Number of fan speeds 2 370 m3/h Max. air flow . RECOMMENDED OPERATING CONDITIONS Room temperature 70°F -90°F (21 ÷ 32°C) Dimensions: • width • height • depth 580 mm 785 mm 435 mm 22 21/64” 30 13/32” 17 1/8” This appliance contains substances which, if released into the atmosphere, would damage the ozone layer.
D ear Customer, Thank you for having purchased an appliance made by De’ Longhi, the international leader in portable air conditioning units. Thanks to our years of experience all around the world we are constantly improving the quality and performance of Pinguino. We are confident that you will be satisfied with your purchase and enjoy the cool comfort created by the Pinguino for many years to come.
• De s c r i p t i o n • De s c r i p t i o n • De s c r i p t c i ó n • De s c r i ç ã o 1 7 6 2 5 8 3 4 9 • CONTROL PANEL • PANNEAU DE COMMANDE • TABLERO DE MANDOS • PAINEL DE COMANDOS 13 15 16 17 18 23 10 11 12 14 19 20 • ACCESSORY-SET • ACCESSOIRES • ACCESORIOS • ACESSÓRIOS 24 21 22 25 27 28 26 29
5751006700/01.