Fryer User Manual

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-1
1.1 Functional Description
High Efficiency Decathlon (HD) Series gas fryers contain a welded stainless steel frypot heated by
gas flames diffused evenly through tubes built into the frypot.
Flames originate from orifices in a burner manifold positioned beneath cast-steel burners. The
burners are positioned in the tube openings at the front of the frypot. The diameter of the orifices
differs for natural and LP gas as indicated in the accompanying table.
GAS INFORMATION (Altitudes of 2000 feet or less)
MODEL
INPUT
(BTU)
GAS
TYPE
ORIFICE
MM
(INCH)
ORIFICE
PART NO.
QTY
EQUIPMENT
PRESSURE
MBAR
INCH W.C.
HD50G 95
NAT
LP
2.26(#43)
1.40(#54)
810-2938
810-2939
4
4
10
27.5
4
10
HD60/63/65G 125
NAT
LP
2.26(#43)
1.40(#54)
810-2938
810-2939
5
5
10
27.5
4
10
An electromechanical gas valve regulates gas flow to the manifold. HD Series gas fryers are
equipped with either a 24V valve system. Unit configurations include either a pilot ignition system