Fryer User Manual
HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS 
CHAPTER 1: SERVICE PROCEDURES 
1-14 
1.7.2 Replacing the Temperature Probe; Controller-equipped Fryers (cont.) 
10. Locate the temperature probe inside the 
frypot. 
11. The temperature probe can be removed 
through the bottom of the frypot as follows: 
Ensure the two-pin connector has been 
removed from the probe wiring harness 
(step 4, above). Carefully bend the two tabs 
(one forward and toward the back) so the 
probe will clear the tabs. Remove the 
harness insulation. The probe can be pulled 
through the frypot from the bottom 
(complete step 7, above, prior to removing 
probe). 
12. Carefully remove the probe from the frypot.  
As the probe is removed, tilt the probe at an 
angle to facilitate removal (curved probes 
only). 
13. Follow the steps on the next page to install 
the new temperature probe. 
IMPORTANT: When installing new probe, use 
Loctite PST567 or equivalent pipe thread sealant 
on threads and ensure probe is positioned properly 
with the mounting hardware installed prior to 
tightening the compression nut. Once tightened, 
the probe cannot be repositioned. 
Locate the temperature probe. 
After removing the probe mounting hardware, the 
temperature probe can be removed through the 
bottom of the frypot. Retain the mounting hardware 
for reassembly. 