DMON-4S Quad (3G/HD/SD)‐SDI to HDMI Multi‐Viewer and Converter Operating Manual for Firmware Version 2.
Introduction Thank you for purchasing the DMON‐4S Quad (3G/HD/SD)‐SDI to HDMI Multi‐Viewer and Converter. The DMON‐4S is a truly portable converter, which incorporates our new easy to use LCD and button control system. The DMON‐4S features 4 independent mini HDMI outputs that can each output any of the four (3G/HD/SD)‐SDI inputs or a Multi‐View of all them.
Main Menus Upon power up the unit will start in the Main Menu pointing to Input Status. The Main Menus are: 1. Input Status 2. Control 3. Multi‐View 4. M.V. Routing 5. M.V. Colours 6. M.V. UMDs 7. M.V. Flip 8. Setup Press the < and > buttons to move left or right through the menus. To enter into a menu press the ENTER button. Notes: 1. Defaults are highlighted in yellow. 2.
3. Control / HDMI Out3 Type (Parameter) This is the current HDMI output type for output 3. This sub menu operates the same as Control / HDMI Out1 Type. 4. Control / HDMI Out4 Type (Parameter) This is the current HDMI output type for output 4. This sub menu operates the same as Control / HDMI Out1 Type. 5. Control / HDMI Out1 Source (Parameter) This is the current source for HDMI output 1. When the sub menu is highlighted, press ENTER to toggle through the following sources: 1.) Multi‐View 2.) Input 1 3.
Multi‐View: (Has SUB‐MENUs) Multi-Viewer MV Audio Source Input 1 Main Menu <== Sub Menu Parameter Window When highlighted in the Main Menu, press the ENTER button to enter this sub‐menu. Press the < and > buttons to move left or right respectively through the 8 menus below and press the BACK button to go back to the Main Menu when finished. The current value for each Sub Menu is shown in the Parameter Window. 1.
5. Multi‐View / MV Audio Source (Parameter) This selects which window the audio is extracted from for the Multi‐Viewer output. When the sub menu is highlighted, press the ENTER button to enter this sub‐menu. Press the < and > buttons to move left or right through the following sources: 1.) Window 1 2.) Window 2 3.) Window 3 4.) Window 4 6. Multi‐View / Reference (Parameter) This is reference for the Multi‐Viewer. When the sub menu is highlighted, press ENTER to toggle through the following selections: 1.
M.V. (Multi‐View) Colours: (Has SUB‐MENUs) M.V. Colours Background Color Black Main Menu <== Sub Menu Parameter Window When highlighted in the Main Menu, press the ENTER button to enter this sub‐menu. Press the < and > buttons to move left or right respectively through the 6 menus below and press the BACK button to go back to the Main Menu when finished. The current value for each Sub Menu is shown in the Parameter Window. 1. M.V.
5. M.V. Colours / Format ForeGrnd (Parameter / Left and Right Adjust) This is the Status Format text colour and transparency setting. When the sub menu is highlighted, press the ENTER button to enter this sub‐menu. Press the < and > buttons to move left or right through the following colours: 1. None 10. Black (Transparent 25%) 19. Blue (Transparent 0%) 2. Black (Transparent 50%) 11. Blue (Transparent 25%) 20. Green (Transparent 0%) 3. Blue (Transparent 50%) 12. Green (Transparent 25%) 21.
5. M.V. UMDs / W3 UMD Enable (Parameter) This enables the UMD on Multi‐View Window 3. When the sub menu is highlighted, press ENTER to toggle through the following selections: 1.) Yes 2.) No 6. M.V. UMDs / W4 UMD Enable (Parameter) This enables the UMD on Multi‐View Window 4. When the sub menu is highlighted, press ENTER to toggle through the following selections: 1.) Yes 2.) No 7. M.V.
7. M.V. Flip / Window 4 H Flip (Parameter) This enables a horizontal flip on Multi‐View Window 4. When the sub menu is highlighted, press ENTER to toggle through the following selections: 1.) No 2.) Yes 8. M.V. Flip / Window 4 V Flip (Parameter) This enables a vertical flip on Multi‐View Window 4. When the sub menu is highlighted, press ENTER to toggle through the following selections: 1.) No 2.
6. SETUP / Demo Cycle Time (Parameter) The Demo Cycle Time determines the amount of time to elapse before cycling to the next item. When the sub menu is highlighted, press the ENTER button to enter this sub‐menu. Press the < and > buttons to move left or right through the time until the unit moves to the next item in the cycle. Default time is 10 Seconds, Maximum time is 256 Seconds Note: The parameter will only be updated when leaving this sub‐menu.