Specifications
O W N E R S M A N U A L
Decware High Fidelity Engineering Co., East Peoria IL, USA www.decware.com
After the bias meters are balanced, you can raise or lower the value of them both at
the same time without loosing the balance between them via this control at the rear of
the amplifier.
The range of this control varies with output tubes. The ideal operating point for KT88’s
in this amplifier would be between 60 and 70 milliamps. 80 milliamps should be
considered the absolute maximum. Running any higher will sacrifice headroom and
create more heat.
This control may be operated while music is playing at normal listening levels or
below. It is common to set this control every time you change output tubes.
NOTE: This amp is compatible with the Tungsol KT120 power tubes IF the bias is
run at the lowest setting. The KT120 tube causes the bias window to shift much
higher. On the lowest setting it will read 80 milliamps whereas the same setting would
read 50 milliamps when a KT88 was used. Run the KT120’s at 80 milliamps.