Setup guide

Goto Camera Preset
It is possible to action a camera to be sent to a preset position when an alarm
zone is triggered.
Highlight the option and press the button to enable this feature.
When enabled a Preset and Camera option will be displayed. Use the
button to move to the preset option, press the or to scroll through the
preset options.
Use the to move to the Camera, use the or to scroll through the
camera numbers. This is the camera that will be automatically sent to the
selected preset position.
Primary Camera for Zone
Zones can be configured to contain one or more cameras.
A still image from the Primary Camera will be;
Used for ‘E-mailing on Alarm’.
Added to the event database.
Will be the first to be displayed (if enabled) on the Operator’s monitor.
Zones that contain more than one camera require this primary camera
reference.
Select Zone Cameras
The cameras that are to be switched to event rate by the zone actions can be
individually selected, or all cameras can be switched.
When the selected cameras option is enabled, use the corresponding camera
key to include / exclude that camera from the zone configuration.
General Contacts
It is possible to configure the alarm contacts independently of camera specific
alarms for specialist applications.
32
ENGLISH
32
Close Relay
It is possible to force a relay to close on receipt of an alarm trigger. The
options available are:
Aux - The are six on-board relays any of these can be selected within this
option.
Module 1 - An additional relay module can be connected via the 485 bus,
one of the sixteen relays can be selected within this option.
Record Still Images
This will record a still image of the alarm camera along with the normal
recording.
Still images are accessible through the Live page of the web interface.
Email Image
When e-mail on alarm is enabled it is possible to attach an image to the
e-mail. An e-mail will be automatically sent to a recipient when an alarm trigger
is received.
Email Image Resolution
This determines the resolution of the attachment within the e-mail. The options
available are:
Thumbnail.
High Resolution.
Medium Resolution
Low Resolution.
It is important to take into account the speed of the remote network link when
configuring this option.
Note: The resolution setting selected is a global resolution and will be common
to all zone and VMD alarms.
Zone 01 Actions
Page Page 3
Enabled
Goto Camera Preset Disabled
Zones 02 - 32, All zones
Apply zone 01 actions to Zone 02