DS2 Setup Guide

Dedicated Micros ©2007
58
DS2
Apply Zone XX actions to
It is possible to apply one conguration to any other zone (there are 32 congurable zones)
individually or apply to all zones. This will save on conguration time when zone action requirements
are the same or similar.
Primary Camera for Zone
Zones can be congured to contain one or more cameras.
A still image from the Primary Camera will be:
Used for ‘E-mailing on Alarm’; Added to the event database; Will be the rst to be displayed (if
enabled) on the Operator’s monitor.
Zones that contain more than one camera require this primary camera reference.
Select Zone Cameras
The cameras that are to be switched to event rate by the zone actions can be individually selected,
or all cameras can be switched.
When the selected cameras option is enabled, use the corresponding camera key to include /
exclude that camera from the zone conguration.
General Contacts
It is possible to congure the alarm contacts independently of camera specic alarms for specialist
applications.
General Contacts
Enabled
Module
Contact
Input Source
End of Line
Nuisance count
Stuck time (mins)
Pulse extension (secs)
1
Aux
01
N/O
00
000
000
2
Aux
01
N/O
00
000
000
1 - 32
Aux, Direct, 01 - 16
01 - 20
N/O, N/C
00 - 15
000 - 999
000 - 999
G
eneral
C
ontact
s
General Contact
The unit has 32 General Contacts that can be accessed and congured within this menu, Use the
button to select the required contact.
Enabled
Each input can be enabled or disabled. Highlight the option and use the or buttons to enable or
disable the input.
Module
The on-board (AUX) alarms and the on-board Direct Alarm modules can be selected for
conguration, as well as module 1 through to module 16.