DS2 Setup Guide

Dedicated Micros ©2007
78
DS2
IP Camera Setup
Camera X
This is the input into the back of the unit. Since this video feed will be via the network, select a
channel that does not have a physical connection.
Type
The unit can recognise a range of IP cameras as well as digital video feeds from NetVu Servers.
These include;
NetVu Server Axis 2120 Axis 206
Axis 211 Axis 2140 Axis 211A
AL9710 JVC VN-C20 Axis 214
JVC VN-C625 JVC VN-C655 Axis 233H
Note: Other cameras utilising the same stream/telemetry protocol as those listed above
will also be supported.
URL
Enter the IP address that will send the IP stream
Port
Enter the port number to be used for this stream.
Camera Number
If a NetVu Server is being used, this parameter will specify which camera number from the Server
will be used to provide the stream.
FPS
Enter the frames per second that the camera has been set to deliver.
Colour Adjust
When the colour bar is selected, press to reduce, and to increase the colour. This option is not
available for IP Cameras.
Note:
This option is not displayed if the camera is set as monochrome.
Contrast Adjust
When the contrast bar is selected, press to reduce, and to increase the contrast. This option is
not available for IP Cameras.
Camera Video Input
This option is only displayed when a camera has failed or is ofine. Select disconnect whilst the
camera is ofine to prevent the camera fail message and alarm being triggered.
If the video input is not to be monitored for camera failure select Connected - Ignore cam fail.
Tip:
This menu can be entered directly by pressing and holding a camera button.
Telemetry
The unit supports control of coaxial and serial telemetry. This option allows the connected dome/PTZ
camera to be congured.