Operating instructions
Dedicated Micros ©2010
11
SD Advanced
Video
8. 16 & 32 way units
VID1 to VID8/VID16/VID32  75Ω BNC composite video input, 1V pk-pk with loop through 1V 
available on 8 and 16 input variants
MON A  75Ω BNC composite monitor output, 1V pk-pk
MON B  Spot Monitor output
MON A  S Video Connection
HDMI  High-Denition Multimedia Interface connector
Note: The position of the HDMI connector will vary dependant on model
Audio
Audio IN (Dual)  RCA (phono) socket, 8KHz/16KHz/22KHz sampling 75Ω input 
impedance, 1V pk-pk
Audio OUT (Dual)  RCA (phono) socket, line level <100Ω output impedance,1V pk-
pk amplication required
Data
SERIAL 1  RS-232 (3 wire & 9 wire)
SERIAL 2  RS-232 (3 wire & 9 wire)
SERIAL 3 (PTZ)  RS-485 (2 wire & 4 wire) 
SERIAL 4 (PTZ)  RS-485 (2 wire & 4 wire) 
USB  2x USB2.0 connectors
IR  Infra-Red Input connector for IR Remote Control Extender 
NET  RJ45 Ethernet network connector, 10/100 Mb/s Ethernet Network
KBD  RJ12 connector for use with Dedicated Micros telemetry
  keyboards (KBC1, KBC2)
EXP  RJ12 expansion port for future use
SATA  E-Sata port available for storage expansion
Alarms and relays
ALARMS IN  Via 25-way (female) D Type 24V 200mA
  20 general alarm inputs
  Range of Alarm states are: 
  i.  0 – 800R = Short circuit
  ii.  800R – 2K = closed contact
  iii.  2k – 12k = open contact
  iv.  > 12K = open circuit
RELAYS  Via 9-way (female) D Type rated at 24V 200mA
  4 onboard light duty relay output (500mA@ 12V-48V Max)
Power
POWER  IEC mains power socket & switch