Operating instructions
Dedicated Micros ©2010
140
SD Advanced
Event Settings
This menu allows actions to be established and congured for the Oracle Dome camera following 
an alarm event. A Home position can be established for the camera and the delay time set for what 
period of inactivity is required before the camera will be sent to its home position.
Camera  Selected camera channel.
Camera Title  Displays the title assigned to the selected camera channel.
Event Name  If required, enter a specic name for the alarm event.
Type  Select the alarm type from: 
EOL (End of Line), NC (Normally Closed), NO (Normally Open) 
or Disabled.
Action  Select a preset position or a patrol action for the camera upon 
alarm event. 
Relay  Select an action for the relay. Select ‘Momentary’ for the relay to 
momentarily switch state. Select ‘Duration’ to switch relay status 
for the duration of the alarm.
Home (Grey)  Select to send the camera to its predetermined home position.
Action  Select a preset or patrol from the accompanying drop down list. 
This preset/patrol will now be set as the cameras ‘home’ position.
Delay  Select the time ( in seconds) for which the camera is inactive i.e. 
no operator input, before returning to its home position.
Save (Grey)  Select to store Event Settings to the unit and the Oracle Dome 
camera memory. 










