Control Conguration
The DM 2060 Dome can be controlled by one of three methods. The conguration drawings show
the three connection arrangements. DM 2060 domes are delivered with the address switches set at
FD (DM/Dennard UTC). DM 2060 with rx domes are delivered with the address switches set at 01.
RS485
The switches on each dome must be set to a unique RS485 camera address, refer to ‘Switch
Conguration - Indoor and Weatherproof Domes ->RS485 Serial Connection’.
1 to 32 Dome Cameras
Video cable
RS 485
Data Link
(Daisy chain)
connect to
controller
Local
230Va.c
input
Local
230Va.c
input
Video cable
To Controller
PSU
PSU
RX100 or AL008 Alarm Card Conguration
The switches on all domes must be set to address 01 by setting blue switch at position 0 and yellow
switch set at position 1, refer to ‘Switch Conguration - Indoor and Weatherproof Domes’.
1 to 16 Dome Cameras
Twisted Pair
(20mA)
(current loop)
4 x local
alarms
4 x local
alarms
Video cable
Video cable
To controller
drx 100
& psu
drx 100
& psu
Breakout
Box
Wiring
Breakout
Box
Wiring