Installation manual

Dedicated Micros ©2009
25
2060
The dome will display its switch setting when rst powered on as the screen will show (in the
example above) “CAM 05”.
Set the individual RS485 address for the dome on the blue and yellow switches tted inside the
dome housing.
Set each switch to its desired position as shown in the table.
Extended RS485 addressing
The dome can be congured to allow up to 239 Dennard or Pelco P RS485 addresses to be used.
The mechanism needs to be removed from the dome to enable this.
1. Follow the instructions to access the address switches, then unscrew 4x posi
screws that hold the mechanism mounting in place and unclip the connector from
the rear.
2. Locate SW3 on the main PCB adjacent to the mounted connector attaching the
daughter board housing the yellow and blue address switches.
3. Set SW3 using the following parameters
Protocol SW3 1 2 3 4 5 6 7 8
Extended Dennard RS485 on off off off off off off off
Extended Pelco RS485 off on off off off off off off
Multi-protocol (default) off off off off off off off off