Installation manual

Dedicated Micros ©2009
9
2060
Safety Bond - Indoor Dome
The safety bond is designed to prevent damage to the dome if it is dropped during installation or
maintenance. It should be connected between the mounting point on the dome and a suitable
secure position, either on the bracket or within the ceiling void. This point should be selected with
the consideration that it will receive the full force of the dome if it is dropped.
For wall, pendant & snowdrop mounted domes;
1. Clip safety bond to the mounting bracket eyelet on ange of bracket to secure.
For standard ceiling mounted domes attach the supplied safety bond;
1. Attach bond to a suitable secure position in the ceiling void.
Note: Always support dome with bond prior to mating connector. The weight of dome should be
supported by bond ensuring no stress is placed on centre connector at any time.