EN Reverse combustion log-fired boiler CBI-II / CBB 15 E User Guide 300019729-001-C
. Contents 1 Used symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2 Important recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2.1 2.2 2.3 3 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2. Important recommendations Congratulations on your choice of a high quality product. We strongly advise you to read the following instructions in order to guarantee the optimal operation of your appliance. We are sure that it will be entirely to your satisfaction and will meet with all of your expectations. 1 Used symbols Caution danger Reference Risk ZRefer of injury and damage to equipment.
2. Important recommendations 2.2 Maintenance - The boiler must be serviced and fully cleaned and the flue gas conduit swept by a qualified professional at least 2 times per year. - We recommend taking out a maintenance contract. - The boiler must be cleaned every 3 to 7 days. - Check the seal on the boiler doors 1 time per month. - Regularly check the level of water in the system and top up if required, taking care that cold water is not added suddenly into the boiler when it is hot.
3. Description 3 Description 3.1 Installing the heating Depending on the heating installation, certain components can be suppressed or added. Get your fitter to explain your installation to you. Description Operation CBI-II Reverse combustion log-fired boiler Burns wood in complete safety and protects the environment. Removes the heat from the fumes given off by combustion and transfers it to the heating water.
3. Description Description Operation DHW pump Heating pump Circulates the heating water from the boiler to the storage tank and from the storage tank to the radiators and brings it back to the boiler where it is reheated. Heating water and heating pipes Motorised mixing valve Pressure gauge Air vent Safety valve Expansion vessel L33 Safety exchanger control valve Carries the heat produced in the boiler to the radiators.
3. Description 3.3 Boiler C002258-B 1. Ash tray door 2. Loading door 3. Control panel 4. Air flap lever 5. Air regulator flap 6. Air regulator flap chain 7. Output modulator: 60-90 °C 8. Safety exchanger (To be connected by the fitter) 9. 95°C limiter thermostat (except CBB 15 E) 10. Sensor tube for the safety exchanger control valve 11. Inspection hatch 12.
3. Description 3.4 Control panel Boiler CBI-II 16 13. General ON 1 / OFF 0 switch C002262-A 17 16. Safety thermostat with manual reset (110 °C) 14. Boiler thermometer 17. Boiler thermostat 15. Flue gas thermostat for extractor fan Boiler CBB 15 E 13. General ON 1 / OFF 0 switch (DHW pump) 14. Boiler thermometer 15.
4. Commissioning 4 Commissioning 4.1 Commissioning Initial commissioning professional. must be done by a qualified 4.2 Subsequent start-ups by the final user (at least at the beginning of the heating season) 1. Check the water pressure in the installation. Top up with more water if necessary. 2. Check that the safety thermostat has not triggered. Remove the safety thermostat hood and press the reset button with a screwdriver - except CBB 15 E. 3.
4. Commissioning 4.3 Ignition 2. Set the On/Off switch to 1. 7. When the wood is well lit (about 20-30 minutes later), continue to fill the combustion chamber. Close the loading door. 3. Pull the lever to open the air flap. 8. Push the lever to close the air flap. 4. Open the loading door. 9. Set the flue gas thermostat between Min and Max (when in operation)*. The fan must continue to turn. 1. Turn the flue gas thermostat to 0 (Ignition) - except CBB 15 E. 5.
5. Cleaning and regular servicing 5 Cleaning and regular servicing Remove ashes from the boiler every 3 to 7 days depending At the end of the heating season, have the on thoroughly the quality and quantity of wood used. cleaned by a qualified professional. boiler Clean the flue gas collector and the fan around 1 time per month. 5.1 Cleaning the boiler (Every 3 to 7 days) 1 MIN 3 5 MAX 0 3 5 2 4 4 C002322-A Turn the boiler off before cleaning. See chapter: Stopping the boiler 4.
5. Cleaning and regular servicing 5.3 Cleaning the flue gas collector (Around 1 time per month) Only on cold boiler. C002260-C Open the inspection hatches and clean with a brush. Remove the ashes via the bottom inspection hatch. 5.4 Cleaning the extractor fan* (Around 1 time per month) *except CBB 15 E - Remove the extractor fan. - Clean the vanes. - Check the squareness of the vanes of the fan. C000 89 5.
6. Stopping the boiler 6 Stopping the boiler 1. Wait until the logs have stopped burning (Wait 3-4 hours). 2. Set the On/Off switch to 0. Specific precautions Outside the heating period: - Thoroughly clean the heating surfaces in the boiler. - Turn on the circulating pumps at least 1 time per month for 2 minutes. Precautions to take if there is a danger of frost Heating circuit: Domestic hot water circuit: Use a correctly dosed antifreeze to prevent the heating water freezing.
7. Troubleshooting 7 Troubleshooting Checks to make before calling your fitter: Faults The boiler stops soon after ignition. The fan often comes on while the boiler is operating. The extractor fan does not work. Flue gases are escaping from the loading door. Probable causes Fault finding The fire has not properly taken (the set temperature has not been reached). The flue gas thermostat has turned the boiler off. Relight the fire. See chapter: Ignition The boiler thermostat is set too low.
7. Troubleshooting Warranty You have just purchased one of our appliances and we thank you for the trust you have placed in our products. Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained. Your fitter and our customer support network are at your disposal at all times.
DE DIETRICH THERMIQUE S.A.S. www.dedietrich-thermique.fr FR Direction des Ventes France 57, rue de la Gare F- 67580 MERTZWILLER +33 (0)3 88 80 27 00 +33 (0)3 88 80 27 99 NEUBERG S.A. www.dedietrich-heating.com DE DIETRICH REMEHA GmbH www.dedietrich-remeha.de DE Rheiner Strasse 151 D- 48282 EMSDETTEN +49 (0)25 72 / 23-5 +49 (0)25 72 / 23-102 info@dedietrich.de LU VAN MARCKE www.vanmarcke.be BE Weggevoerdenlaan 5 B- 8500 KORTRIJK +32 (0)56/23 75 11 RU DE DIETRICH www.dedietrich-heating.