Technical data
18
MCR 24, 24/28 MI, 30/35 MI, 34/39 MI 08/06/06-300008460-001-B
The boiler must not be positioned above a heat source or a
cooking appliance
- The boiler must be fixed to a solid surface, capable of bearing the
weight of the appliance and other equipment when full of water.
- To enable removal and replacement of the cladding, a space of 5
mm is sufficient on either side of the boiler.
- The IPX4D protection index authorises installation in bathrooms,
except for protection volumes 1 and 2 however.
Comply with current regulations.
If using thermostatic valves, it is not necessary to fit them to every
radiator.
Never fit radiators in the room in which the room
temperature thermostat is installed with thermostatic
valves.
Certificate of compliance
For the application of article 25 of the modified decree dated 02/08/
1977 and of article 1 of the modifed decree dated 05/02/1999, the
installation engineer must be in possession of the certificates of
compliance approved by the Ministries in charge of construction and
gas safety:
- Different forms (forms 1, 2 or 3) for a new gas installation,
- "Model 4" in particular after replacing a furnace with a new one.
In order to avoid damage to the boilers, it is necessary to
prevent the contamination of combustion air by chlorine
and/or fluoride compounds, which are particularly
corrosive. These compounds are present, for example, in
aerosol sprays, paints, solvents, cleaning products,
washing products, detergents, glues, snow clearing salts,
etc.
Therefore:
- Do not suck in air evacuated from premises using such
products: hairdressing salons, dry cleaners, industrial
premises (solvents), premises containing refrigeration
systems (risk of refrigerant leakage), etc.
- Do not stock such products close to the boilers.
If the boiler and/or peripheral equipment are corroded by
such chloride or fluoride compounds, the contractual
guarantee cannot be applied.