. Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.1 1.2 Symbols and abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1. Introduction 1 Introduction 1.1 Symbols and abbreviations In these instructions, various markings and pictograms are used to draw your attention to particular information. In so doing, De Dietrich Thermique S.A.S. wishes to safeguard the user's safety, obviate hazards and guarantee correct operation of the boiler. Caution danger Risk of injury and damage to equipment.
1. Introduction 1.
2. Safety instructions and recommendations 2 Safety instructions and recommendations 2.1 Safety instructions 2.1.1 Fire hazard IfDANGER you smell flue gases: IfDANGER you smell gas: 1. Do not use a bare flame, do not smoke, do not actuate electrical contacts or switches ( doorbell, light, motor, lift, etc..). 1. Switch the appliance off 2. Open the windows. 2. Cut the gas supply. 3. Evacuate the premises 3. Open the windows. 4. Call your fitter 4. Evacuate the premises. 5. Call your fitter. 2.
3. Description 3 Description 3.1 General description The SGC 24 SOL solar column is a multi-energy unit which includes a gas-fired condensing boiler and a 200-litre solar domestic hot water tank in the same casing. The boiler is preset in the factory to operate on natural gases H and E (Operating pressure: 20 mbar). The boiler is fitted with a system to protect against overheating. 3.
3. Description Position Key T Description - . : Shutdown/antifreeze/vent. 6-position switch - : Domestic hot water (Summer). - " : Heating and domestic hot water (Winter). V : Measurement mode (Key to access the parameters reserved for the installer). - K : Fitter mode (Key to access the parameters reserved for the installer). - M : Sweeping mode (Key to access the parameters reserved for the installer).
4. Operating instructions 4 Operating instructions 4.1 Start the boiler ` Check the water pressure in the installation several times a year. If necessary, top up the boiler with water. The water pressure in the installation must be between 1.5 and 2 bar. ` Open the gas valve. ` Set the 6-position switch T to (summer mode) or (winter mode). ` If using a room temperature thermostat or a communicating remote control, turn them to heating request.
4. Operating instructions 4.3 Changing the settings 4.3.1 Set the 6-position switch T to the desired operating mode. C000879-B ` Selecting the operating mode - - . : Shutdown/antifreeze/vent. - - : Domestic hot water (Summer). - - " : Heating and domestic hot water (Winter). 4.3.2 Set the temperature of the heating water using button V. C000880-C ` Changing the heating temperature - Minimum = 30 °C - Maximum = 90 °C - Hard point = 68 °C ` The temperature set in shown on the display.
4. Operating instructions 4.5 Prolonged absence 4.5.1 Switching off the appliance If the central heating system is not used for a long period, we recommend switching the boiler off. 1. Switch the boiler off. 4.5.2 2. Cut the power supply to the boiler. 3. Close the gas valve. Antifreeze protection The boiler must be installed in a frost-free environment. We recommend setting the boiler thermostat to a value off 10°C if using a classic installation.
5. Checking and maintenance 5 Checking and maintenance 5.1 General instructions Maintenance operations must be done by a qualified An annual inspection is compulsory. professional. We recommend that you take out a maintenance contract. Only original spare parts must be used. ` Regularly check the water pressure in the installation (minimum pressure 0.8 bar, recommended pressure between 1.5 and 2 bar).
5. Checking and maintenance 5.4 Bleeding the heating system It is essential that you vent any air in the appliance, the ducts or the valves to prevent the noise annoyance likely to be produced during heating or water draw-off. 6. Bleed the radiators. Start with the lower floors. To do this, proceed as follows: 1. Open the valves on all radiators connected to the heating system. 5 3 4 1 2 1 2 3 4 T000181-B 2. Set the heating set point to as high a temperature as possible. 3.
5. Checking and maintenance 5.5 Draining the installation It may become necessary to empty the water from the heating system when the radiators have to be replaced, should there be a major water leak or a risk of frost. To do this, proceed as follows 1. Open the valves on all radiators connected to the heating system. 1 2 3 4 T000181-B 2. Cut the power supply to the boiler. 3. Wait around 10 minutes until the radiators are cold. T000185-A 4.
6. Troubleshooting 6 Troubleshooting 6.1 Breakdown codes In the event of a fault, the display indicates an alarm message by alternately showing AL and a code from which the type of fault can be determined. 6.1.
6. Troubleshooting 6.3 Incidents and solutions Checks to make before calling your fitter 6.3.1 The burner is not working It is cold. ` Check the boiler thermostat settings. ` If using a room temperature thermostat or a remote control (Easymatic or Easyradio), check that it is set according to the instructions. It is cold. There is no domestic hot water C002175-A ` Note the code displayed AL + _ _. ` Press button Q until the red light goes out. ` Release the button.
6. Troubleshooting 6.3.2 The burner is operating but the radiators are cold Air and water noise in the radiators ` Bleed the radiators. ` Top up the heating circuit with water. ` If it is often necessary to top up the installation with water, contact your fitter. ` If the problem persists, consult your fitter. The burner is operating but the radiators are cold ` Check that the boiler heating pump is operating correctly. ` If the problem persists, consult your fitter 6.3.
7. Technical characteristics 7 Technical characteristics Boiler SGC 24 SOL General Useful output 50 / 30 °C Nominal output (heating and DHW modes) Minimum output kW 6.0 Useful output 80 / 60 °C Nominal output kW 22.0 (heating and DHW modes) Minimum output kW 5.7 Power input Nominal output kW 22.8 (heating and DHW modes) Minimum output kW 5.9 Operating efficiency 80 / 60 °C (4) % 107.8 40 / 30 °C (4) % 110.
7. Technical characteristics Boiler SGC 24 SOL Dimensions Height mm 1710 Width mm 600 Depth mm 657 Shipping weight kg 196 (3) Cold water temperature: 10 °C (1) Heat exchanger inlet temperature: 80 °C Domestic hot water temperature: 45 °C (2) DHW setting: 60 °C Average domestic hot water temperature: 40 °C Boiler setting: 80 °C 8 Energy savings 8.1 Energy-saving advice ` Keep the room in which the boiler is installed well ventilated. ` Close the radiators in rooms not in use.
7. Technical characteristics Warranty You have just purchased one of our appliances and we thank you for the trust you have placed in our products. Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained. Your fitter and our customer support network are at your disposal at all times.
DE DIETRICH THERMIQUE S.A.S. www.dedietrich-thermique.fr FR Direction des Ventes France 57, rue de la Gare F- 67580 MERTZWILLER +33 (0)3 88 80 27 00 +33 (0)3 88 80 27 99 T000249-B NEUBERG S.A. www.dedietrich-heating.com DE DIETRICH REMEHA GmbH www.dedietrich-remeha.de DE Rheiner Strasse 151 D- 48282 EMSDETTEN +49 (0)25 72 / 23-5 +49 (0)25 72 / 23-102 info@dedietrich.de LU DE DIETRICH www.dedietrich-otoplenie.ru VAN MARCKE www.vanmarcke.