User guide
7
15/10/2009 - 300017555-001-C SGC 24 SOL
3. Description
3.3 Parameter display - Diemasol A solar regulator
` To scroll the parameters, push on key < or >.
T 6-position switch -
.
: Shutdown/antifreeze/vent.
-
: Domestic hot water (Summer).
-
"
: Heating and domestic hot water (Winter).
-
V
: Measurement mode (Key to access the parameters reserved for the installer).
-
K
: Fitter mode (Key to access the parameters reserved for the installer).
-
M
: Sweeping mode (Key to access the parameters reserved for the installer).
U "Heating" on light The light is on when the heating/domestic hot water reversal valve is in the heating position and the
circulator pump is operating.
V Heating temperature setting Adjustment range : 30 °C to 90 °C (Hard spot at 68°C).
W Flame presence light The light is on when the burner is operating.
X Setting the domestic water
temperature
Adjustment range : 40 °C to 60 °C (Hard spot at 55°C).
Y "Domestic hot water" on light The light is on when the heating/domestic hot water reversal valve is in the domestic hot water
position and the circulator pump is operating.
Z Pressure indicator Indicates the pressure in the heating circuit from 0.5 to 2.5 bar.
Position Key Description
Abbreviation Parameter Range
TC Collector temperature [-50.0...+250.0°C]
TS Tank temperature [-50.0...+250.0°C]
kWh Amount of heat [0...9999 kWh]
PC Pump regime [0...100 %]
tc Self-calibration time [0...5] minutes
TR Return temperature [-50.0...+250.0°C]
TM Additional temperature
with S3 sensor only (optional)
[-50.0...+250.0°C]