User manual

Table Of Contents
Hardware description |
Seite 37
2.2.2.4.2. Setting up the CAN module address
Any connected device to the CAN network needs a fix address in order to be
directly accessed. With the 11 DIP-switches, up to 2047 different addresses are
selectable. Further 18 addressing bits may be supplemented by software. To
unlock this option, DIP-switch 7A must be set to ON.
Baud rate
Bit
Value ON
Value OFF
DIP-switch A3
Bit 10
1024
0
DIP-switch A2
Bit 9
512
0
DIP-switch A1
Bit 8
256
0
DIP-switch B8
Bit 7
128
0
DIP-switch B7
Bit 6
64
0
DIP-switch B6
Bit 5
32
0
DIP-switch B5
Bit 4
16
0
DIP-switch B4
Bit 3
8
0
DIP-switch B3
Bit 2
4
0
DIP-switch B2
Bit 1
2
0
DIP-switch B1
Bit 0
1
0