Scope of Delivery
1 x RF-160
1 x Screwdriver
1 x AC cable with outdoor plug, 16 ft. (5 m)
1 x Outdoor ethernet cable, 32 ft. (10 m)
1 x Bag with the 5 parts of the outdoor housing for prewired RJ45 cordset and a quick manual
1 x Fall protection ring
1 x Installation manual
1 x Safety information
1 x Product registration document (this information is only needed for a cloud based sensor operation and is
provided by an enclosed document or online by the Dedrone Service)
The original packing carton is the safest container in which to transport the unit and must be used if
returning the unit for service. Save it for possible future use.
4 Scope of Delivery
Verify that all the parts listed in the scope of delivery are included. If any items are missing, notify
your Dedrone Partner.
Do not use this product if any component appears to be damaged. Please contact Dedrone in the
event of damaged goods.
5 Select the Mounting Place
The position of the RF-160 has strong impact to the detection range. The RF-160 is intended for an
installation on top of a pole. Make sure that a suitable pole is available (diameter between 1.2 in to
3.1 in (40 mm to 80 mm)).
5.1 Detection Conditions
For ideal results the location should fulfill the following conditions:
` Clear view over the area
` Exposed, elevated position (minimum 10 ft (3 m))
Do not install the device nearby the following objects:
Metal surfaces or vaporized glass
Disturbs the detection.
Walls
These share the detection area and prevent classification of signals behind the wall.
Base station and other strong signale sources