Section 6 –Accidental Release Measures
Emergency treatment: Cut off the fire source. It is suggested that the staff wear self-contained breathing apparatus. Shut off
the divulgence source as soon as possible. Prevent skin contact and collect all released material in a plastic lined metal
container. Prevented the spillage to flow into restrictive space like the sewer and the drainage channel. Small amount of
divulgence: sweep. Massive divulgence: Build diking or dig pit to accept, recycle or transport to waste treatment place for
handling.
Section 7 - Handling and Storage
Handling: To supply with sufficient air exhaust. The operating staff must have received special trainting and abide by the
operanting regulations. In the event of a battery rupture, prevent skin contact and collect all released material in a plastic lined
metal container. Keep away from fire and heating sources. No smoking in the workplace.
Storage: These cells and batteries shall not be stored in high temperature, the maximum temperature is 45(less than one
month), otherwise the cells and batteries maybe leakage. Besides, the cells and batteries shall be protected from short circuit
and protected from movement that could result in short circuit.
Section 8 - Exposure Controls, Personal Protection
Maximum admissible concentration: No standard yet
Monitoring Method: /
Engineering Control: To supply with sufficient partial air exhaust.
Respiratory Protection: Use NOISH/MSHA approved respirator if cell broken open during a fire to maintain exposure levels
below the TWA for cadmium and nickel compounds.
Eyes Protection: Use splash goggles or face shield if cell activates due to abuse.
Body Protection: Wear work clothes.
Hands Protection: If exposure to electrolyte solution, or dried salts is likely, use any water-insoluble non-performance glove,
i.e., synthetic rubber. Do not use leather or wool.
Other Protections: No smoking, dining and drinking water in the workplace. Keep good habit of hygiene.
Section 9 - Physical and Chemical Properties
Flash Point: /
Appearance: Geometric solid object
Boiling Point: /
Proportion: /
Specific Gravity:
1.17-1.250(electrolyte)
Acid Value: /
PH Value: /
Permission of solvent inhalation: /
Solubility:
Electrolyte solution is completely soluble
Section 10 - Stability and Reactivity
Stability: Stable under normal temperature.
Distribution of Ban: Aluminum, zinc and other active metals, acid, chlorinated and aromatic hydrocarbons, nitro carbons,