INSTALLATION INSTRUCTIONS CONSOLE Air conditioners SILHOUETTE CONSOLES SPLIT CONSOLES CURTAIN WALL CONSOLES www.defy.co.za The Manufacturer strives for continuous improvements. For this reason, the text and illustrations in this book are subject to change without notice.
Installation notes. To ensure optimum performance and customer satisfaction, please read these instructions carefully. All Defy Console type air-conditioners are tested and rated using the standard Defy wall sleeve and louvre assembly. Units can safely operate up to 43°C outdoor temperature. They have been designed to produce the rated capacity at the lowest power consumption under International Standard Rating conditions.
Silhouette Console Installation instructions MOUNTING HOLES 900 550 720 390 735 220 400 CONSOLE UNIT 405 310 335 MOUNTING HOLES WALL SLEEVE 745 100 WALL APERTURE 100mm. ABOVE FINISHED FLOOR LEVEL (INDOOR) PRIOR TO INSTALLATION • • • • • • • • Remove the filter assembly. Loosen the two screws at the bottom corners of the access cover and remove it. Loosen the two screws at either end of the fan deck. Disconnect the multi-plug and slide the fan deck out.
Split Console installation instructions ELECTRICAL CONNECTIONS NOTE. • • A 16A mains cable is connected to the indoor unit. • If this cable is too short, a qualified electrician should replace it. • An interconnecting cable complying with local wiring codes, should be connected between the indoor and outdoor units. 1. Connect the brown wire to terminal 1 2. Connect the blue wire to terminal 2 3.
Installation of the Outdoor unit • • • • • • Ensure that the voltage is 230V 50Hz. Also check that the model and capacity matches those of the indoor unit. Select a position for the outdoor unit which allows for the shortest possible unobstructed pipe length. Ensure that the air intake and discharge are unobstructed and that there is enough room for servicing. Provide a concrete base or sturdy mounting plate and bolt the unit down using anti-vibration pads to reduce vibration and noise.
“This appliance must be earthed and the manufacturer and the seller do not accept responsibility for any damage due to incorrect installation or electrical connection.” Electrical Installation INTER CONNECTING WIRING DIAGRAM FOR SPLIT EVAP AND CONDENSER SECTION INTERCONNECTING SPLIT EVAP. AND COND. WIRING DIAGRAM 1 BLACK BLACK BLUE 1 N1 N1 N2 N2 N2 N2 H H HH WHITE / BROWN 2 BROWN GREEN / YELLOW CONNECTING CABLE WIRING TERM.
Curtain Wall Console Installation Instruction 95 410 815 405 810 WALL APERTURE WALL SLEEVE 60 PRIOR TO INSTALLATION • • • • • • Remove Front Inlet Grille and store in a safe place. Remove both Filter Assemblies and store with the front inlet grille. Remove the two screws securing the Front Cover assembly to the Chassis Assembly. Remove the Front Cover assembly Two mounting holes, located on the Condenser Back Cover, are now exposed and clearly visible.
Defy branch Sales Phone JOHANNESBURG PRETORIA BLOEMFONTEIN DURBAN CAPE TOWN PORT ELIZABETH NAMIBIA BOTSWANA SWAZILAND ( AGENT) 011 621 0200 —————— 051 400 3900 031 460 9649 021 551 8314 041 401 6400 09264 61 216162 09267 306476 09268 518 6527 Parts Fax Phone Fax 011 621 0399 —————— 051 400 3950 031 460 9631 021 551 8228 041 401 6501 09264 61 216134 09267 359705 09268 518 4318 011 621 0200 012 377 0061 051 400 3900 031 460 9712 021 551 8314 041 401 6400 ————— ————— ————— 011 621 0396 012 377 0398 05