Chapter 2 Installation 2-7
2. Align the holes on a mounting ear with a corresponding pair of 12.7-mm (0.5-in. or
1/2-in.) rack holes.
The rack holes are not evenly spaced between each other along the rack. Some are
12.7-mm (0.5-in. or 1/2-in.) spaced, and some are 15.875-mm (0.625-in. or 5/8-in.)
spaced. Only 12.7-mm (0.5-in. or 1/2-in.) spaced holes are used for the mounting
ears.
FIGURE 2-7 Aligning the Mounting Ear Holes With the Rack Holes
3. Attach the mounting ears to the media tray front sides.
■ If you are mounting the media tray in the Sun Enterprise system cabinet, align
only the mounting ear rear holes to the media tray front side holes, as shown in
FIGURE 2-8 B.
■ If you are mounting the media tray in the Sun StorEdge expansion cabinet, align
the mounting ear front and rear holes to themedia tray front and rear side holes, as
shown in
FIGURE 2-8 A.