Data Sheet

Specifications subject to change without notice
ATS 036T Desktop Power Supply 25 W 36 W
P: C14 Inlet (Protection Class I)
A: C8 Inlet (Protection Class II)
Features
Compliant to DoE 2016 (Level VI)
ErP Stage 2, NRCan & GEMS Level VI
No Load Power Consumption < 0.1 W
Regulated Output with Low Ripple Noise
1 Year Warranty
Marks / Approvals
Specifications
MODEL
Voltage
Min. Load
Max. Load
Max. Power
ATS 036T-P/A050
5.0 V
0.00 A
5.00 A
25 W
ATS 036T-P/A075
7.5 V
0.00 A
4.00 A
30 W
ATS 036T-P/A085
8.5 V
0.00 A
3.52 A
30 W
ATS 036T-P/A090
9.0 V
0.00 A
3.34 A
30 W
ATS 036T-P/A120
12.0 V
0.00 A
3.00 A
36 W
ATS 036T-P/A135
13.5 V
0.00 A
2.66 A
36 W
ATS 036T-P/A150
15.0 V
0.00 A
2.40 A
36 W
ATS 036T-P/A160
16.0 V
0.00 A
2.25 A
36 W
ATS 036T-P/A180
18.0 V
0.00 A
2.00 A
36 W
ATS 036T-P/A240
24.0 V
0.00 A
1.50 A
36 W
ATS 036T-P/A480
48.0 V
0.00 A
0.75 A
36 W
INPUT
Voltage
AC 100 V 240 V
Frequency
50 Hz - 60 Hz
Current
1.00 A max.
Protection
Internal Primary Current Fuse, Inrush Limiting
OUTPUT
Load Regulation
± 5 % (typical)
Ripple
1 % 2 % V p-p max. for output voltage at full load
Transient Response
0.5 ms for 50 % load change typical
Leakage Current
0.25 mA max.
Protection
Short circuit Protection ▪ Over Voltage Protection ▪ Over Current Protection
OTHERS
Cooling
Convection
Efficiency
DoE Level VI ▪ Energy Star ▪ ErP Stage 2 ▪ NRCan & GEMS Level VI Certified
Holdup Time
10 ms at full load
Dielectric Withstand
AC 3000 V Primary Secondary
MTBF
300,000 calculated hours at 25 °C by telcordia SR-332
ENVIRONMENT
Temperature
Operating: 0 °C 40 °C / Storage: -20 °C 80 °C
Humidity
Operating: 20 % RH 80 % RH / Storage: 10 % RH 90 % RH
EMI Conduction &
Radiation
Harmonic Current
EMS Immunity
Safety
Case Dimensions
Weight

Summary of content (1 pages)