Features
■ Compliant to DoE 2016 (Level VI)
■ ErP Stage 2, NRCan & GEMS Level VI
■ No Load Power Consumption < 0.1 W
■ Regulated Output with Low Ripple Noise
■ 1 Year Warranty
Marks / Approvals
Specifications
MODEL
Voltage
Min. Load
Max. Load
Max. Power
ATS 250T-P120
12 V
0.00 A
20.00 A
240 W
ATS 250T-P150
15 V
0.00 A
16.66 A
250 W
ATS 250T-P190
19 V
0.00 A
13.15 A
250 W
ATS 250T-P240
24 V
0.00 A
10.42 A
250 W
ATS 250T-P480
48 V
0.00 A
5.21 A
250 W
ATS 250T-P560
56 V
0.00 A
4.46 A
250 W
INPUT
Voltage
AC 100 V – 240 V
Frequency
50 Hz - 60 Hz
Current
3 A max.
Protection
Internal Primary Current Fuse, Inrush Limiting
OUTPUT
Load Regulation
± 5 % (typical)
Ripple
1 % – 2 % V p-p max. for output voltage at full load
Transient Response
0.5 ms for 50 % load change typical
Leakage Current
0.25 mA max.
Protection
Short circuit Protection ▪ Over Voltage Protection ▪ Over Current Protection
OTHERS
Cooling
Convection
Efficiency
DoE Level VI ▪ Energy Star ▪ ErP Stage 2 ▪ NRCan & GEMS Level VI Certified
Holdup Time
10 ms at full load
Dielectric Withstand
AC 3000 V Primary – Secondary
MTBF
300,000 calculated hours at 25 °C by telcordia SR-332
ENVIRONMENT
Temperature
Operating: 0 °C – 40 °C / Storage: -20 °C – 80 °C
Humidity
Operating: 20 % RH – 80 % RH / Storage: 10 % RH – 90 % RH
EMI Conduction &
Radiation
Compliance to EN 55022 Class B
Harmonic Current
Compliance to EN 61000-3-2, -3
EMS Immunity
Compliance to IEC 61000-1-2, -3, -4, -5, -6, -8, -11
Safety
IEC / EN / UL 62368-1 ▪ IEC 60950-1 ▪ CE ▪ RCM ▪ PSE ▪ BSMI
Case Dimensions
204 x 94 x 43.5 mm
Weight
1 040 g typical