Data Sheet

22.10.2019
6W
Wall mount
SYS1638-Wxx series
RoHS
GREEN MODE
Country of Origin :
Operating Temperature :
Efficiency level (ErP) :
China
0~40 [°C]
VI
Approvals / Marks :
Specifications
Model
Voltage DC
[V]
Loading
[A]
Max. Power
[W]
Ripple / Noise
[mV] p-p
Connector
[mm]
SYS1638-0605-Wxx 5 0~1.2 6 250 2.1x5.5x11
SYS1638-0605-Wxx 5 0~1.2 6 250 Mini USB
SYS1638-0605-Wxx 5 0~1.2 6 250 Micro USB
SYS1638-0605-Wxx 5 0~1.2 6 250 USB inlet
SYS1638-0612-Wxx 12 0~0.5 6 200 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2C - China | W2K - Korea
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
CE
EMC
2014/30/EU
LVD
2014/35/EU
EN 62368-1
SAFETY
cULus / FCC / CB / CE / GS
OTHERS
Dielectric Strength(Hi-pot)
Primary to Secondary:4000VAC 10mA/60S
M.T.B.F
500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Cable Length
1500mm (5 feet) standard cable or as required
PLD
(power line disturbance)
Line power surge | Line voltage SAG-more info on request
Cooling method
Natural Convection Cooling
Housing material
PC
Temperature coefficient:
< ±0.5% / ºC
ENVIRONMENT
Temperature
Operating: 0~40ºC / Storage: -20~85ºC
Humidity
Operating: 8%~90%RH / Storage: 5%~95% RH non condens-
ing
WEIGHT
1PC
NW: 79g/pc
GW: 95g/pc
PACKING
PE plastic bag 100 pcs /1 box
OUTPUT
Turn delay
3000ms max@AC low line input@output full load
Hold up time
5ms min@AC nominal input@output full load
Efficiency (Normal)
>79.03%@115v/60HZ,230V/50HZ input &Full load
Transient response
(dv,tmax)
0.6V dv max At AC nominal input loading from 20%load to 80%
load
Dynamic rise time 10 us max,duty 40ms max,Dynamic load step
is slew rate of 0.5A/us
Power out.Limit
6W
Burn in limit
Full load 2 Hours
Power consumption
0.075W max. At AC nominal input@output min load
INPUT
Voltage
(90~264)VAC
Frequency
(47~63)hz
Current
0.5A rms@AC low line input and DC output full load
Inrush Surge Current
(cold start)
40/60A max@power supply cold start,ambient temperature 25ºC
@115Vac/230Vac nominal AC input
leakage current
0.25mA Max
PROTECTION
Over current/
Short protection
The power supply will be auto recovered when over current or
short circuit faults remove (fold back). Is defined as any output
impedance of less than 0.1Ω.The power supply will be auto
recovered when short circuit faults remove
Over Voltage
The power supply will not be auto recovered when faults remove
110%-150%. (Voltage limit)
Input protection
F1 1A/250V Fuse The power supply shall be protected against
power line surges and any abnormal condition
No Load protection
The power supply is provided with no load operation to prevent
the power supply and system from damage.
Protection class
II
www.sunny-euro.com

Summary of content (2 pages)