User's Guide

www.dejero.com
67 | Dejero EnGo 3x User Guide
Problem Error /
warning
number
Description Solution
Latency is being
adjusted to
optimize the
requested
operation. This
message will
automatically clear
when the latency
adjustment has
completed.
Warning 120 The CellSat service
requires a minimum latency
of 1.5 seconds. The device
is adjusting the latency from
a lower level.
Wait for the device to adjust the latency.
SSL Handshake
failed
Warning 121 The SSL handshake failed
due to poor network
conditions.
Wait for network conditions to improve
and try again.
Requested latency
setting is too low
Error 125 The assigned receiver is
not capable of a latency of
less than 0.8 seconds.
Assign this source to a receiver with a
compatible latency setting or contact
Dejero Support for assistance.
Hardware failure Error 200 The input device has
malfunctioned.
Contact Dejero Support.
Software failure Error 201 The software stopped
unexpectedly and was
restarted automatically.
Contact Dejero Support.
Technical specifications
Video
Resolutions 1080p 23.98/25/29.97/30/50/59.94/60 (3G-SDI Level-A), 1080i
25/29.97/30, 720p 50/59.94/60, 576i 25, 480i 29.97
Encoding H.264 AVC and H.265 HEVC, adaptive encoding
Inputs 3G/HD/SD-SDI, HDMI 1.0