Installation Manual

DEKOLINK WIRELESS LTD. PRODUCT MANUAL IDEN REPEATER
Alarm Indication Probable Cause Recommended Action
Fan Failure Fan Failed - Check power supply
- Check fan.
External Alarm Connectivity - Check connection to Alarms
connector.
Downlink/Uplink
Lock Detect alarm
Faulty status of the
Phased Locked Loop
(PLL) in the
Channeler unit
- Reboot the Repeater.
- Check the connection
between the Controller and the
Channeler (*).
(*) If the indication remains after the Recommended action procedure, replace the
Repeater.
The following troubleshooting procedures refer to communication failures, and are
not shown in the Repeater Alarms screen.
Failure Probable Cause Recommended Action
Connection to the
Controller failed in
the local connection
Communication
failure
- Check the physical connection
between the PC COM1 and the
Controller RS232 interface.
- Verify that the LED of the
controller is blinking rapidly.
- Reboot the Repeater.
- Restart the PC.
- Re-install the Controller software
Connection with
the Repeater failed
in the remote
connection
Communication
failure
- Check that the modem is physically
connected to the controller serial
input.
- Verify that the modem local port
baud rate is 57,600 bps.
- Verify that the Controller LED is
blinking.
- Verify that the modem is connected
to the antenna cable via the RF
coupler.
- Restart the PC.
- Reinstall the Controller software.
Pub. 307-2005 Rev. 1.0 Proprietary Data Page 27