3.2 FBDA ALARM SPECIFICATIONS
Remote Fault Indication
(Summarized alarm)
Alarm is sent on the serial data link of the FO transmitter
to FBIU
Fault List : Power Supply Over-voltage or Under-voltage
Uplink Amplifier Over Current or Under Current
Downlink Power Amplifier Over Current or Under Current
FO Transceiver Over Current or Under Current
FO Receiver Power fall (Bad Optical Connection)
Fan Over Current or Under Current
Electrical Fault
Indication LED
Illuminated LED on Monitor Box for each Electrical Fault
Fiber Optic Connection
Fault Indication LED
Illuminated LED on FO Transceiver when Optical
Connection is performing Correctly.
LED is OFF when FO Receiver Power falls.
FBIU alarm output Dtyp 9pin male, N.C. relay contact between pin 2 and pin
4, open for active alarm + Illuminated LED on front panel.
3.3 MECHANICAL SPECIFICATIONS:
FBDA FBIU
Size 400 x 400 x 300 mm approx. 19” 1Ux250mm
Weight 25 kg. Approx. 3 kg. Approx.
Type Weatherproof Enclosure for
Wall Mounted Installation
In door, rack mount
Power Supply 110 VAC / 2A or 220VAC/1A 110/220VAC
(0PTIONAL -48V DC 1A)
3.4 ENVIRONMENTAL CONDITIONS:
Operating temperature
- 30°
C to + 50
°
C
Storage temperature
- 30°
C to + 70
°
C
Weatherproof conditions Protected to IP65 (FBDA only)