Operating Instructions

Dekolink WIRELESS Ltd.
16 Bazel St. Qiryat-Arieh Petah-Tikva, Israel, 49510
Tel- 972-3-9180-180 Fax-972-3- 190-9180
e-mail: marketing@decolink.com
web www.decolink.com
4. INSTALLATION PROCEDURE
4.1 Fiber Optic Link Assembly:(both FBDA and FBIU)
4.1.1 Insert main optical fiber trough the Fiber In/out hole on the FBDA
panel and connect it to the Optical In/out connector on the Fiberoptic
transceiver. On the FBIU connect the optical fiber to the Optical In/out
connector on the Fiberoptic transceiver.
4.1.2 Insert diversity optial fiber trough the Fiber in/out hole on the FBDA
panel and connect it to the Optical out connector on the Fiberoptic
transmitter. On the FBIU connect the diversity optical fiber to the Optical In
connector on the Fiberoptic receiver.
4.2 Downlink calibration:
4.2.1 Connect Spectrum analyzer through High Power Attenuator of 40 dB to
the Antenna port of the FBDA.
4.2.2 Inject (+20) dBm signal at 880 MHz from the FBIU Tx antenna through
the optical link.
4.2.3 Adjust Gain on the Fiberoptic transceiver front panel in the FBDA so
that RF power at the output is +30dBm.
4.3 Uplink calibration:(both main and diversity path)
4.3.1 Connect Spectrum analyzer to the Rx port of the FBIU.
4.3.2 Inject (–60) dBm signal at 835 MHz from the antenna port on the FBDA
side through the optical link.
4.3.3 Adjust Gain on the Fiberoptic transceiver in the FBIU so that RF power
at the output is -44 dBm.
4.3.4 Repeat the above with the diversity path.
Page
9 of
9
FO-800AB-50W SYS.doc