Next Generation Corona Discharge Auto Voltage Sensing EC-10, EC-20 & EC-40 Installation Manual 4-2162-01 Rev.
IMPORTANT SAFETY INSTRUCTIONS Read & Follow All Instructions • Read this manual completely before attempting installation. Failure to install in accordance with the installation instructions could void warranty and result in injury or death. • The DEL Eclipse electrical connection is to be attached to the pool controls, be sure the pool controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.). If the DEL Eclipse is connected to an independent electrical supply, then a G.F.C.I.
Eclipse Installation & Operations Manual Table of Contents Installation Instructions SECTION 1. Overview............................................................................. 1 SECTION 2. Installation.......................................................................... 2 SECTION 3. Operation............................................................................ 6 SECTION 4. Maintenance....................................................................... 7 SECTION 5. Replacement Parts....
Eclipse Installation & Operations Manual 1C. Warranty Summary Limited Warranty: 1 year warranty on entire generator. See Warranty section for limitations and details on obtaining warranty service. SECTION 2. Installation 2A. Location The DEL Eclipse units are designed for wall mounting. Mount generator in a clean, protected area, either indoors or outdoors (preferably out of direct sunlight). Locate generator out of reach of sprinklers or drainage spouts.
Eclipse Installation & Operations Manual near the top on the left and right and one located in the center near the bottom. Refer to Figure 1 for clarification. 2. Install screws (or other hardware appropriate for the mounting surface) through the two mounting holes near the top of the enclosure. Install the last screw through the mounting hole near the bottom of the enclosure. Mounting hardware must be driven until the head fully contacts the enclosure wall.
Eclipse Installation & Operations Manual after all other pool equipment (pump, filter, heater, and cleaner). Figure 2 shows the most basic installation. For installation with additional sanitizers and pool cleaners, refer to Appendix A. Eclipse System Heater Filter Pool Pump Injector Manifold Water Flow Figure 2: Injector Manifold Mounting Location Locate an appropriate section of the return line and install the injector manifold with PVC cement.
Eclipse Installation & Operations Manual Eclipse System Ozone Tube Ozone Outlet Barb Flow Meter Assembly (Remove after testing) Check Valve Tube Adapter Injector Assembly Figure 3: Flow Test Assembly 2D-4. Flow Test - Refer to Figure 3. 1. Install Tube Adapter on injector. Use Teflon thread tape as needed. 2. Connect the end of the Ozone Tube with the check valve installed onto the Tube Adapter with the tube clamp provided. 3.
Eclipse Installation & Operations Manual provides a wide operating range. If more gas flow is necessary, verify that other valves in the system are not inhibiting flow through the Manifold. If you experience complications see TROUBLE SHOOTING Section 4D. 7. After the system has been set for the correct flow rate. Remove the Flow Meter Assembly and connect the remaining end of the Ozone Tube to the Ozone Outlet Barb on the DEL Eclipse unit with the tube clamp provided.
Eclipse Installation & Operations Manual 3D. System Shut-Down The following sequence of steps must be followed for servicing or for storage. 1. Disconnect the power to the ozone generator. 2. After the generator has been shut down, the pool water circulation pump may be turned off. 3. If the system is to be shut down for an extended period, disconnect the Ozone Tube from the unit. 3E. Water Chemistry Regular chlorine or bromine testing should be performed as normal.
Eclipse Installation & Operations Manual 4A-1. Ozone Module The Eclipse Ozone Generators are constructed with high voltage plasma gap Ozone Modules. The EC-10, EC-20, and EC-40 have 2, 4, and 6 modules, respectively. Each module has an indicator light that signals it’s working properly. If the light goes out, replace the module. 4B. System Maintenance 4B-1. The green indicator lights on the Ozone Modules located inside the enclosure indicates that the Power Supply is operating properly.
Eclipse Installation & Operations Manual 4C-2. Ozone Module Replacement The EC-10, EC-20, and EC-40 have 2, 4, and 6 Ozone Modules, respectively. When the green indicator lights go out, the corresponding Ozone Module will need to be replaced. To replace an Ozone Module: 1. Disconnect the Ozone Module from the Manifold and pull the Ozone Module from the Bracket so it hangs by its wires. 2. Locate the Power Supply Connector and disconnect it from the wire harness. 3.
Eclipse Installation & Operations Manual e. Be sure that the check valve has not become fouled with debris. Disconnect the Ozone Tube from the injector. With the pump running, cover the end of the injector with your thumb, and feel for suction. If there is sufficient suction without the check valve, replace the check valve with a new one. 4D-3 Symptom: Ozone Tube becomes yellow/brown and brittle. 1.
Eclipse Installation & Operations Manual 5B. Standard replacement parts list: 1. Ozone Module Kit.................................................9-1056-01 Each ozone module should be replaced after 15,000 hours of use. 2. Ozone Tube Assembly..........................................9-0770-02 The Ozone Tube Assembly (includes Ozone Tube and Check Valve) must be replaced once a year. Note: The warranty is void if the parts listed above are not replaced at recommended intervals.
Eclipse Installation & Operations Manual DEL OZONE Eclipse™ LIMITED 1 YR WARRANTY The limited warranty set forth below applies to products manufactured by DEL OZONE – 3580 Sueldo Street, San Luis Obispo, California 93401, and sold by DEL OZONE or its authorized dealers. This limited warranty is given only to the first retail purchaser of such products and is not transferable to any subsequent owners or purchasers of such products.
Eclipse Installation & Operations Manual Eclipse Installation – Plumbing The DEL Ozone Eclipse works under vacuum. The Injector Manifold draws the ozone/air gas mixture out of the ozone generator and mixes it into the water leaving behind some un-dissolved gas bubbles. These bubbles can affect certain pool system components, so care must be taken when installing the ozone Injector Manifold. The diagrams below cover common plumbing configurations.
3580 Sueldo Street, San Luis Obispo, CA 93401 (800) 676-1335 o3info@delozone.com www.delozone.com EPA Estab. No.